In tissue engineering research, generating constructs with an adequate extent of clinical applications remains a major challenge. In this context, rapid blood vessel ingrowth in the transplanted tissue engineering constructs is the key factor for successful incorporation. To accelerate the microvascular development in engineered tissues, we preincubated osteoblast-like cells as well as mesenchymal stem cells or a combination of both cell types in Matrigel-filled PLGA scaffolds before transplantation into the dorsal skinfold chambers of balb/c mice. By the use of preincubated mesenchymal stem cells, a significantly accelerated angiogenesis was achieved. Compared with previous studies that showed a decisive increase of…
Bone marrow derived mesenchymal stem cells (bmMSCs) are widely used for the generation of tissue engineering constructs, since they can differentiate into different cell types occurring in bone tissues. Until now their use for the generation of tissue engineering constructs is limited. All cells inside a tissue engineering construct die within a short period of time after implantation of the construct because vascularization and establishment of connections to the recipient circulatory system is a time consuming process. We therefore compared the influences of bmMSC, VEGF and a combination of both on the early processes of vascularization, utilizing the mice skinfold…
The demanding need for tissue replacement resulted in manifold approaches for the construction of different tissues. One common problem which hampers the clinical usage of tissue engineering constructs is a limited vascularization. In an attempt to accelerate the vascularization of tissue engineering constructs we compared the usage of bone marrow mesenchymal stem cells (bmMSCs) and fragments derived from the aorta in vivo. Tissue engineering constructs composed of PLGA scaffolds containing Matrigel (n = 8), aortic fragments embedded in Matrigel (n = 8), bmMSCs embedded in Matrigel (n = 8), and aortic fragments embedded in Matrigel combined with bmMSCs (n =…
The faith of tissue engineered bone replacing constructs depends on their early supply with oxygen and nutrients, and thus on a rapid vascularization. Although some models for direct observation of angiogenesis are described, none of them allows the observation of new vessel formation in desmal bone. Therefore, we developed a new chamber model suitable for quantitative in vivo assessment of the vascularization of bone substitutes by intravital fluorescence microscopy. In the parietal calvaria of 32 balb/c mice a critical size defect was set. Porous 3D-poly(L-lactide-co-glycolide) (PLGA)-blocks were inserted into 16 osseous defects (groups 3 and 4) while other 16 osseous…
Angiogenic and inflammatory responses to biodegradable scaffolds were previously studied using the dorsal skinfold chamber for testing different scaffold materials. In this model, the angiogenic response originates from the soft tissue of the skin. Herein, we introduce a new model that allows the study of developing microcirculation of bone defects for testing tissue-engineered constructs. A bone defect was prepared in the femur of Balb/c mice by inserting a pin for intramedullary fixation, and a custom-made observation window fixed over the defect allowed constant observation. This study included three different groups: empty defect (control), defect filled with porous poly(l-lactide-co-glycolide), and beta-tricalcium-phosphate…
The implantation of tissue-engineered constructs leads to hypoxic and physical stress to the seeded cells until they were reached by a functional microvascular system. Preconditioning of cells with heat shock induced heat shock proteins, which can support the cells to survive a subsequent episode of stress that would otherwise be lethal. Preconditioning of tissue-engineered constructs resulted in significantly higher number of surviving osteoblast-like cells (OLC). At the 6th and 10th day, angiogenic response was found comparative to poly(L-lactide-co-glycolide) (PLGA) scaffolds vitalized with either unconditioned or preconditioned OLC. However, they were significantly enhanced compared with the nonvitalized collagen-labeled PLGA scaffolds. This…
Adequate vascularization of tissue-engineered constructs remains a major challenge in bone grafting. In view of this, we loaded ß-tricalcium-phosphate (ß-TCP) and porous poly(L-lactide-co-glycolide) (PLGA) scaffolds via collagen coating with vascular endothelial growth factor (VEGF) and studied whether the VEGF loading improves scaffold angiogenesis and vascularization. Dorsal skinfold chambers were implanted into 48 balb/c mice, which were assigned to 6 groups (n = 8 each). Uncoated (controls), collagen-coated, and additionally VEGF-loaded PLGA and ß-TCP scaffolds were inserted into the chambers. Angiogenesis, neovascularization, and leukocyte-endothelial cell interaction were analyzed repeatedly during a 14-day observation period using intravital fluorescence microscopy. Furthermore, VEGF release…